Intracellular Imaging, Inc. - InCyt I/P-2 Imaging & Photometry System

InCyt High Speed I/PTM                                  (click image to enlarge and get detailed specs)

Complete Turnkey System

The InCyt High Speed I/PTM Imaging and Photometry System includes everything needed for calcium and other single excitation and ratiometric fluorophore experiments. The system includes: an inverted epi-fluorescence/phase contrast microscope, microphotometer assembly, low-light level integrating CCD camera, computer controlled fast changing monochromator with Xenon arc lamp, image processing computer and data acquisition/analysis software.

Ease-of-use

The InCyt High Speed I/PTM Imaging and Photometry System was designed in a biomedical research laboratory by scientists for scientists. Menu selection appears in the sequence in which experiments are performed. Esoteric options that add complexity and are rarely used have been eliminated from the menus. The software follows standard Windows graphical-user-interface-protocol. The hardware has been tested for reliability and ruggedness, as well as, simplicity of set up and operation. New users can learn to use the system and be doing their first experiment in a few hours.

 

Data Collection, Analysis & Presentation

Imaging data can be measured continuously on as many as 50 pre-selected regions of interest. The results can displayed in real time or images can be saved for post hoc analysis. Saved images can be played back as an animated sequence—ideal for analysis of sub-cellular responses, intercellular communication and heterogeneity among the individual cells in a population. Ion concentration within cells can be converted to color using standard or custom pseudo-color tables. Image sequences can be presented as a montage with user-defined annotation for presentation and publication. Data generated by InCyt High Speed I/PTM are stored in a standard TIFF format and data files are stored as ASCII text.


Specifications

Camera Module
CameraDVC 340M Monochrome Integrating 12-bit CCD with Binning Capabilities
Excitation wavelength changerTill Polychrome V fast changing monochromator with Xenon arc lamp
Image Resolution640 x 480 pixels


Photometer Module
PMTHamamatsu H7360-01 photon counter
Linearity (precision)+/-1% from 0 to 20,000,000 counts/second
Maximum Dark Count (noise)150 counts/second
Equivalent Noise Input (noise)3 x 10-17 watts per second (measured at 400nm)
Spectral Sensitivity300-650nm
Discriminator & MicroprocessorBuilt into PMT
Overload ProtectionComputer-controlled shutter (optional)
Excitation wavelength changerTill Polychrome V fast changing monochromator with Xenon arc lamp


Image/Data Acquisition and Analysis Workstation
CPUIntel®  CoreTM  2 Duo Processor E4600 (2.4GHz, 2M, 800MHz FSB)
RAM2GB SDRAM,667MHz
Hard Drives80GB/160GB SATA 3.0Gb/s and 8MB DataBurst Cache
DVD ROM16X DVD +/- R/W
Operating SystemWindows XP
Monitor17" SVGA


Image Data Capture and Display
Maximum Speed 20 ratiometric points per second
140 single-wavelength points per second
Object DefinitionSpecify up to 50 user-defined regions for separate analysis
Data Collection Options(1) Graph ion concentration in each cell during experiment.
(2) Save images for later analysis and animated playback
Image FormatTIFF
Data Storage FormatTab-delimited ASCII


PMT Capture and Display
Maximum Speed150 ratiometric measurements per second
1000 single-wavelength measurements per second
Time LapseUp to 1 measurement every 10 minutes
Field of ViewRectangular area, user-definable
Graphic DisplayReal-time during experiment
Data Storage FormatTab-delimited ASCII


Other
CalibrationFrom standard solutions, formula, or in situ
IonsWorks with hundreds of fluorescent dyes for measuring: Ca2+, pH, Na+, K+, Mg+2, H2O2, cyclic ADP Ribose, etc.


Imaging Data Presentation

 